SECOLink 64 rása öryggiskerfi KM24G
P64KM24G er start pakki sem samanstendur af P64 stjórnborði og KM24G töluborði. Stjórnborðið er 64 rása og er gert bæði fyrir víraða og þráðlausa skynjara. Stjórnborðið er einnig með inngang fyrir víraða reykskynjara.
Möguleiki er að bæta við stækkunarborð til að fjölga inngöngum og útgöngum. Lyklaborð styður allt að 64 skynjara i einu kerfi og 4 svæða skiptingu. Kerfið er sett saman miðað við fjölda og gerð skynjara sem v.v. þurfa.
Features | P64 |
Alarm system concept | Hybrid modular system |
On-board wired zones | 7/14 (doubling) |
2-wire smoke detector input | 1 |
On-board wireless zones | 64 |
Maximum zones in system | 64 |
On-board PGM | 3 |
Maximum PGM in system | 16 |
User + installer codes | 63+1 |
Duress code | |
Defaulting user code | Yes |
Key switch zone | Yes |
Partitions | 4 |
"Shared" partition (common area) | Yes |
System timers | 16 |
Maximum keypads/modules in system | 15 |
Keypad compatibility | Only KM24G |
Event log buffer | 512 |
PSTN communicator | Plug-on |
In-built interface for backup communicator | TTL Serial |
Data bus protocol | KRBUS |
Total phone numbers: CMS reporting + personal dialing | 9 |
Maximum phone numbers for personal dialing | Up to 5 |
Maximum phone numbers for CMS reporting | Up to 4 |
Reporting protocol | Contact ID |
Voice guide for system control over PSTN | Yes |
Voice guide for system programming over PSTN | Yes |
"Roller" detector type | Yes |
"Vibration" detector type | Yes |
"Vibration" zone speed (sensitivity) | 0.01 - 0.25 sec. |
Normal zone speed (sensitivity) | 0.1 - 2.5 sec. |
Zone loop (detector) type | |
Arming mode | Away, Max Away, Night, Stay. |
Zone definition | Entry/exit, entry/exit forced, interior, interior night armed, follower, follower night armed, perimeter, instant, PGM control; |
24h: burglary, panic silent, panic audible, tamper, fire, smoke, fire button, medical button, fire supervisory, low water level, RF Jam, gas detected, water leakage, high temperature, low temperature | |
Zone attributes | Enable bypass, no alarm, arm when door is closed, entry route, exit route, fire verification, limitation of alarms, limitation of reporting, pre-alarm, armed night |
PGM definition | Fire alarm, fire/burglary alarm, burglary alarm, tamper alarm, technical alarm, selected alarms, chime, zone violation, bypass status, selected trouble, exit/entry warning, exit/arm status, full arm status, power supply, resettable power supply, fire power supply, timer, mono/bi switch |
PGM attributes | Inversion, pulsation, latch, pre-alarm, arm notification, arming failure notification, disarm notification, clear alarm notification, armed in specific mode |
Rated voltage of power supply (AC) | ~20 V |
Minimum AC voltage | ~16 V |
(note: ~16 V input voltage lets control panel to generate max 0.7 A output current) | |
Maximum AC voltage | ~22 V |
(Note: higher than ~22 V voltage can damage control panel) | |
Maximum long term output current of control panel | ≤2.0 A |
(I+AUX + I+BELL + I+PGM + battery charge): | |
Maximum current of slow blowing fuse used in primary AC | 250 mA |
Maximum AC power consumption | 150 mA |
Minimum voltage on +AUX, +BELL, +PGM outputs | 12 V |
Maximum voltage on +AUX, +BELL, +PGM outputs | 13.9 V |
Maximum current out of +AUX | +1 A |
Maximum current out of +BELL | +2 A |
Maximum current into -PGM | -0.3 A |
Maximum current out of +PGM | +0.9 A |
Short circuit, overload protection of +BELL, +PGM, +AUX | Electronic |
Battery charge, +BELL, +AUX current measurement | Yes |
Failed (waste) backup battery disconnection | Yes |
Maximum battery charging current | 0.35 A |
Maximum current of fast blowing fuse used in battery circuit | 3.15 A |
Control panel disconnect battery when it’s voltage less than | 9.5 V |
Recommended backup battery | 12 V, 7 Ah / 20 Hr |
Operational compliance | +EN50131, Grade2 |
Overall dimensions W x H in mm | 145 x 77 |
Environmental compliance | ROHS |
Operating temperature | |
Production status | In production |
Latest firmware version | v0.03 |
In-field firmware upgrade (by USB) | Yes |